Real-Time Field Intelligence · Microcontroller Edge Nodes

Sensors that understand photosynthesis before the harvest ends.

Edge telemetry nodes deployed across your farm capture NPK, moisture, microclimate, and light data in real time. The edge computes locally; only insights flow to the cloud. This page shows the system architecture, sensor types, and integration specifications for developers deploying hardware.

Data Flow: From Soil to Decision Engine

1
Field Sensors
XRF, NIR, soil probes, microclimate stations capture raw field data every 15 minutes.
2
Edge Node
Microcontroller (ESP32 / ARM) aggregates sensor feeds, runs validation, buffers data locally.
3
Local Compute
Edge node runs NPK efficiency model (same logic as digital-twin page) to detect anomalies before cloud sync.
4
Cloud Archive
Insights and exceptions sync to QAgroTrust backend. Full history stays on farm device for offline operation.

Sensor Suite Deployed Per Field

🧪

XRF Spectrometer

Elemental analysis of soil: N, P, K, Ca, Mg, S, micronutrients. Non-destructive, field-ready.

Range: 0–500 ppm · Accuracy: ±2% · Update: 4x/season
📐

NIR Leaf Probe

Chlorophyll index via near-infrared reflectance. Correlates directly with N status in plant tissue.

Wavelength: 650–2500 nm · Resolution: ±0.2 SPAD · Update: Daily at 10:00 UTC
💧

Soil Moisture & EC

Volumetric water content & electrical conductivity (salt stress detection). Multi-depth probes.

Depth: 15, 30, 45 cm · Range: 0–100% VWC · Update: Every 30 min
🌡️

Microclimate Station

Temperature, relative humidity, wind speed, rainfall. Integrated Davis / Vaisala class equipment.

Accuracy: ±0.3°C, ±2% RH · Data rate: 5-min intervals
☀️

PAR (Light) Sensor

Photosynthetically active radiation (400–700 nm). Measures actual light capture capacity.

Range: 0–2500 µmol/m²/s · Accuracy: ±5% · Sample rate: 1 Hz
🛰️

GPS / RTK Positioning

Field geolocation for spatial NPK mapping. RTK module for cm-level accuracy in precision applications.

Accuracy: ±2.5 m (GPS) / ±2 cm (RTK) · Update: 1 Hz

Data Schema: Telemetry Payload

Every 15 minutes, the edge node sends telemetry to POST /api/telemetry/ingest. This is the contract for integrating new sensor types.

Field Type Example Notes
farmId string "FARM-0847" Unique farm identifier from portal
fieldName string "Field A North Block" Human-readable field name
lat, lng float 12.4537, 78.9423 GPS coordinates (WGS84)
timestamp ISO8601 "2026-07-20T14:32:00Z" UTC timestamp of reading
n_kg_ha, p_kg_ha, k_kg_ha float 124.5, 38.2, 151.8 NPK in kg/hectare (from XRF or lab assay)
soil_moisture_pct float 58.3 Volumetric water content 0–100%
temp_c, rh_pct float 28.5, 67.2 Temperature (°C) and relative humidity (%)
par_umol_m2_s float 1240 Photosynthetically active radiation
chlorophyll_spad float 42.8 Relative chlorophyll content (SPAD index)
edge_confidence float 0.94 Local model confidence (0.0–1.0) — anomaly if <0.7
Sample API Request
POST /api/telemetry/ingest
Authorization: Bearer FARM_TELEMETRY_TOKEN_FARM_0847
Content-Type: application/json

{
  "farmId": "FARM-0847",
  "fieldName": "Field A North Block",
  "lat": 12.4537,
  "lng": 78.9423,
  "timestamp": "2026-07-20T14:32:00Z",
  "n_kg_ha": 124.5,
  "p_kg_ha": 38.2,
  "k_kg_ha": 151.8,
  "soil_moisture_pct": 58.3,
  "temp_c": 28.5,
  "rh_pct": 67.2,
  "par_umol_m2_s": 1240,
  "chlorophyll_spad": 42.8,
  "edge_confidence": 0.94
}

🔗 For Hardware Teams & Developers

To deploy edge telemetry on a new farm: provision an ESP32 or Raspberry Pi with LoRaWAN or 4G connectivity, load the qagrotrust-edge-firmware (available on NRDC tech portal after TRL clearance), wire the sensor suite above, and point the device to api.qagrotrust.com/api/telemetry/ingest with a farm-issued authentication token. The firmware handles local NPK modeling, outlier detection, and offline buffering. No custom coding required — just sensor wiring and power.

Real-Time Metrics Computed at Edge

The edge node runs the same photosynthesis efficiency engine as the digital-twin page, but locally, every 15 minutes. Anomalies (efficiency <65%) trigger immediate farm alerts before data reaches the cloud.

Metric Computation Trigger
Photosynthetic Efficiency % scoreAgainstOptimum(N, P, K) via edge Node.js runtime Alert if < 65%
Irrigation Recommendation IF soil_moisture < 40% AND par > 1000: increase water Push to farmer app in real-time
Disease Risk Score IF rh > 85% AND temp 20–28°C: elevated risk Alert if risk > 0.7
Nutrient Leaching Risk IF rainfall > 40mm AND n_kg_ha drops >15%: flag leaching Advisory: split dose recommended